ALL PERMIT FEES WILL NEED TO BE PAID BY CHECK OR EXACT CASH ONLY.
WE APOLOGIZE FOR THIS INCONVENIENCE.
A COMPLETED APPLICATION IS REQUIRED TO OPEN A CONSTRUCTION OR OPERATIONAL PERMIT.
**PERMITS WILL NOT BE REVIEWED OR PROCESSED WITHOUT PAYMENT**
105.1.1 Permits required. A property owner or owner’s authorized agent who intends to conduct an operation or business, or install or modify systems and equipment that are regulated by this code, or to cause any such work to be performed, shall first make application to the fire code official and obtain the required permit.
Annual Operational Permit Application
105.7 Required Construction Permits. The fire code official is authorized to issue construction permits for work as set forth in Sections 105.7.1 through 105.7.25.
PLEASE FILL OUT PRIOR TO PRINTING
Fire Sprinkler System Construction Permit Application
Kitchen Hood System Construction Permit Application
Fire Alarm System Construction Permit Application
Miscellaneous Construction Permit Application
Application, plans and payment can be submitted in person at the Fire Station or by emailing the application and plans to jmalone@cityofdixon.us
Once application is submitted, payment can be made in person with check or credit card or by mailing a check.
No. | Title | Notes | ||||
---|---|---|---|---|---|---|
105.7.1 | Automatic Fire-Extinguishing Systems: Fire Sprinkler System Kitchen Hood System | A construction permit is required for installation of or modification to an automatic fire-extinguishing system. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.2 | Battery Systems | A construction permit is required to install stationary storage battery systems regulated by Section 1206.2 | ||||
105.7.3 | Capacitor Energy Storage Systems | A construction permit is required to install capacitor energy storage systems regulated by Section 1206.3 | ||||
105.7.4 | Compressed Gases | Where the compressed gases in use or storage exceed the amounts listed in Table 105.6.8, a construction permit is required to install, repair damage to, abandon, remove, place temporarily out of service, or close or substantially modify a compressed gas system. | ||||
|
| Exceptions:
| ||||
105.7.5 | Cryogenic Fluids | A construction permit is required for installation of or alteration to outdoor stationary cryogenic fluid storage systems where the system capacity exceeds the amounts listed in Table 105.6.10. Maintenance performed in accordance with this code is not considered to be an alteration and does not require a construction permit. | ||||
105.7.6 | Emergency Responder Radio Coverage System | A construction permit is required for installation of or modification to emergency responder radio coverage systems and related equipment. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. | ||||
105.7.7 | A construction permit is required for installation of or modification to fire alarm and detection systems and related equipment. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. | |||||
105.7.8 | Fire Pumps and Related Equipment | A construction permit is required for installation of or modification to fire pumps and related fuel tanks, jockey pumps, controllers and generators. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. | ||||
105.7.9 | Flammable and Combustible Liquids | A construction permit is required:
| ||||
105.7.10 | Fuel Cell Power Systems | A construction permit is required to install stationary fuel cell power systems. | ||||
105.7.11 | Gas Detection Systems | A construction permit is required for the installation of or modification to gas detection systems. Maintenance performed in accordance with this code is not considered a modification and shall not require a permit. | ||||
105.7.12 | A construction permit is required for the installation of or modification to a gate or barricade across a fire apparatus access road. | |||||
105.7.13 | Hazardous Materials | A construction permit is required to install, repair damage to, abandon, remove, place temporarily out of service, or close or substantially modify a storage facility or other area regulated by Chapter 50 where the hazardous materials in use or storage exceed the amounts listed in Table 105.6.20. | ||||
|
| Exceptions:
| ||||
105.7.14 | High-Piled Combustible Storage | A construction permit is required for the installation of or modification to a structure exceeding 500 square feet, including aisles, for high-piled combustible storage. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. | ||||
105.7.15 | Industrial Ovens | A construction permit is required for the installation of industrial ovens covered by Chapter 30. | ||||
|
| Exceptions:
| ||||
105.7.16 | LP-Gas | A construction permit is required for installation of or modification to an LP-gas system. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.17 | Motor Vehicle Repair Rooms and Booths | A construction permit is required to install or modify a motor vehicle repair room or booth. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.18 | Plant Extraction Systems | A construction permit is required for installation of or modification to plan extraction systems. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.19 | Private Fire Hydrants | A construction permit is required for the installation or modification of private fire hydrants. Maintenance performed in accordance with this code is not considered to be an alteration and does not require a permit. | ||||
105.7.20 | Smoke Control or Smoke Exhaust Systems | Construction permits are required for installation of or alteration to smoke control or smoke exhaust systems. Maintenance performed in accordance with this code is not considered to be an alteration and does not require a permit. | ||||
105.7.21 | Solar Photovoltaic Power Systems | A construction permit is required to install or modify solar photovoltaic power systems. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.22 | Special Event Structure | A single construction permit is required to erect and take down a temporary special event structure. | ||||
105.7.23 | Spraying or Dipping | A construction permit is required to install or modify a spray room, dip tank or booth. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. | ||||
105.7.24 | Standpipe Systems | A construction permit is required for the installation, modification or removal from service of a standpipe system. Maintenance performed in accordance with this code is not considered a modification and does not require a permit. | ||||
105.7.25 | Temporary Membrane Structures and Tents | A construction permit is required to erect an air-supported temporary membrane structure, a temporary state canopy or a tent having an area in excess of 400 square feet. | ||||
|
| Exceptions:
|